The differences between solenoid valve and electric valve
This article introduces the differences between solenoid valves and electri...
HMT 4-20ma Modulating Multi-turn Electric Actuator is used to control the open and close of valves. It is applicable to gate valves, globe valves, shut-off valves, diaphragm valves, and its derivative products can be applied to ball valves, butterfly valves and dampers, etc. It can accurately operate according to control commands, which is essential driving device for remote control, centralized control and automatic control of valves.
The HMT series is used to control the open and close of valves. It is applicable to gate valves, globe valves, shut-off valves, diaphragm valves, and its derivative products can be applied to ball valves, butterfly valves and dampers, etc. It can accurately operate according to control commands, which is essential driving device for remote control, centralized control and automatic control of valves.
Model |
Output Torque |
Output Speed |
Motor Power |
Rated Current |
Manual Speed Ratio |
Maximum Stem Diameter |
Reference Weight |
Remarks |
HMT005 |
50 |
24 |
0.12 |
0.6 |
1:60 |
28 |
20 |
|
HMT010 |
100 |
24 |
0.18 |
1 |
1:60 |
28 |
20 |
|
HMT015 |
150 |
24 |
0.25 |
1.2 |
1:60 |
28 |
20 |
|
HMT020 |
200 |
24 |
0.37 |
1.38 |
1:60 |
40 |
26 |
|
HMT030 |
300 |
24 |
0.55 |
2.7 |
1:60 |
40 |
26 |
|
HMT045 |
450 |
24 |
1.1 |
4 |
1:60 |
48 |
110 |
|
HMT060 |
600 |
24 |
1.5 |
4.12 |
1:60 |
48 |
120 |
|
HMT090 |
900 |
24 |
2.2 |
5.25 |
1:60 |
60 |
139 |
|
HMT120 |
1200 |
24 |
3 |
7.9 |
1:60 |
60 |
142 |
|
HMT180 |
1800 |
24 |
4 |
8.87 |
1:60 |
70 |
250 |
|
HMT250 |
2500 |
18 |
5.5 |
12.05 |
22.5:1 |
70 |
255 |
|
HMT350 |
3500 |
18 |
7.5 |
15.6 |
20:1 |
80 |
330 |
|
HMT500 |
5000 |
18 |
10 |
20.5 |
20:1 |
80 |
350 |
|
Parameter |
Transfer Matrix (Jb2920) |
Thrust Type (GB/T1222-2005) |
|||||||||||||||
Cabin Seat |
D |
D1 |
D2 |
d2 |
d1 |
h |
h1 |
f |
n-d |
Flange |
D |
D1 |
D2 |
D1 |
n-d |
f |
|
HMT010-015 |
2 |
145 |
120 |
90 |
45 |
30 |
8 |
2 |
5 |
4-M10 |
F10 |
125 |
102 |
70 |
Tr28 |
4-M10 |
3 |
2I |
115 |
95 |
75 |
39 |
26 |
6 |
2 |
4 |
4-M8 |
||||||||
HMT020-030 |
3 |
185 |
160 |
125 |
58 |
42 |
10 |
2 |
5 |
4-M12 |
F14 |
175 |
140 |
100 |
Tr236 |
4-M16 |
4 |
3I |
145 |
120 |
90 |
45 |
30 |
8 |
2 |
5 |
4-M10 |
||||||||
HMT045-060 |
4 |
225 |
195 |
150 |
72 |
50 |
12 |
2 |
5 |
4-M16 |
F16 |
210 |
165 |
130 |
Tr244 |
4-M20 |
5 |
HMT090-120 |
5 |
275 |
235 |
180 |
82 |
62 |
14 |
2 |
5 |
4-M20 |
F25 |
300 |
254 |
200 |
Tr260 |
8-M16 |
5 |
5I |
230 |
195 |
150 |
72 |
50 |
12 |
2 |
5 |
4-M16 |
||||||||
HMT180-250 |
7 |
330 |
285 |
220 |
98 |
72 |
16 |
3 |
6 |
4-φ27 |
F30 |
350 |
298 |
230 |
Tr270 |
8-M20 |
5 |
HMT350 |
8 |
380 |
340 |
280 |
118 |
82 |
20 |
3 |
3 |
8-φ22 |
F35 |
415 |
356 |
260 |
Tr280 |
8-M30 |
5 |
Description:
1.The I in the frame number indicaes the power station type;
2.The diameter of the trapezoidal middle trapezoidal threa is the largest diameter;
3.The position of the mounting hole of the connecting plate is symmetrically distributed with the motor axis.
Model |
L |
L1 |
H |
H1 |
F1 basic type |
F2 smart type |
φD |
HMT005-015 |
660 |
370 |
330 |
120 |
280 |
400 |
200 |
HMT020-030 |
710 |
380 |
340 |
130 |
300 |
420 |
200 |
HMT045-060 |
740 |
390 |
350 |
140 |
330 |
450 |
270 |
HMT090-120 |
800 |
400 |
360 |
150 |
380 |
500 |
270 |
HMT180-250 |
870 |
565 |
600 |
250 |
740 |
535 |
550 |
HMT350 |
1170 |
770 |
710 |
280 |
840 |
450 |
570 |
2024
/
This article introduces the differences between solenoid valves and electri...
2024
/
Rotork: Rotork is a global leader in the design and manufacture of industri...
2023
/
Ecwatech exhibition is the leading water and wastewater technology fair in ...
2023
/
After the valve is installed, carry out commissioning of the electric actua...
GET A QUOTE